A bottle of water or paraffin, a coil wound round it and a frequency counter make an instrument that measures the Earth's magnetic field to a part in a million with no calibration at all. The protons in the liquid precess about the field at 42.577 hertz per microtesla, a constant fixed by the proton itself, so the Earth's field is an audio tone of about two kilohertz. The difficulty is that the Earth's field lines up only two protons in ten billion. The instrument polarises them with a strong coil first, and then has to switch the coil off in a few milliseconds — because if it is switched off slowly, the protons follow the turning field round and end up pointing exactly where they can no longer be heard.

Assumes: The image made of frequencies · The angular momentum that is not a rotation

Archaeologists surveying a field for buried walls, oil companies mapping the rocks under a sea, navies looking for submarines and geophysicists watching the Earth’s field change from hour to hour have all used, for seventy years, an instrument whose working part is a bottle of liquid. It holds half a litre of water, kerosene or alcohol, wrapped in a coil of wire. A few seconds of current through the coil, then a pause, then a faint audio tone in the same coil, fading away over a second or two; the tone’s pitch is the measurement. A field of fifty microtesla gives 2,128.9 hertz, and so does every other fifty-microtesla field anywhere in the universe, because the pitch is set by the proton.

The instrument is the proton precession magnetometer, and it is the simplest practical use of nuclear magnetic resonance. It also depends on a point that is easy to get backwards: the way the strong polarising field is removed decides whether there is anything to hear.

The pitch of a proton

A proton has a spin and a magnetic moment along it. The angular momentum that is not a rotation found that this spin cannot be pictured as a spinning ball, but in a magnetic field the average moment of many protons behaves exactly as a spinning top’s axis does under gravity: the field exerts a torque on the moment, the torque is at right angles to the angular momentum, and the moment precesses round the field without changing its angle. The image made of frequencies used that precession in a hospital scanner, at 63.87 megahertz in a field of 1.5 tesla. The rate is the gyromagnetic ratio times the field,

f=γ2πB,γ2π=42.577 MHz/T=42.577 Hz/µT.f = \frac{\gamma}{2\pi}B, \qquad \frac{\gamma}{2\pi} = 42.577 \text{ MHz/T} = 42.577 \text{ Hz/µT}.

In the Earth’s field, the same protons precess thirty thousand times more slowly. The rate does not depend on the angle between moment and field, which is what makes it a clean measure of the field: a top’s precession rate depends on how fast it spins and how heavy it is, as the top that nods before it settles followed in detail, but a proton’s spin and moment are fixed, and only the field is left to set the rate.

The Earth's field is an audio tone. The frequency at which proton moments precess, (γ/2π)B with γ/2π = 42.577 MHz per tesla, against the strength of the Earth's field, which ranges from about 22 µT over South America to 66 µT near the magnetic poles. Every value is in the audible range, 1277 Hz at 30 µT and 2555 Hz at 60 µT. A buried iron object or a basalt dyke changing the field by 1 nT changes the tone by 0.0426 Hz, and since γ is fixed by the proton, a frequency measurement is an absolute measurement of the field with no calibration.
Fig. 1 The frequency at which proton moments precess, (γ/2π)B(\gamma/2\pi)B with γ/2π=42.577\gamma/2\pi = 42.577 MHz per tesla, against the strength of the Earth’s field, which ranges from about 22 µT over South America to 66 µT near the magnetic poles. Every value is in the audible range, 1,277 Hz at 30 µT and 2,555 Hz at 60 µT. A buried object or a basalt dyke changing the field by 1 nT changes the tone by 0.0426 Hz.

The Earth’s field varies from about twenty-two microtesla over the South Atlantic to sixty-six near the magnetic poles, so the protons sing between nine hundred hertz and two and a half kilohertz, in the middle of the audible range. An iron cannon buried two metres down changes the field above it by a few nanotesla, a basalt dyke under a field by tens, and each nanotesla moves the tone by 0.0426 hertz. Measuring the field to a nanotesla therefore means measuring a frequency near two kilohertz to two parts in a hundred thousand.

What makes the instrument special is that the conversion from frequency to field contains only γ\gamma. The proton’s gyromagnetic ratio is a constant of nature, measured to better than a part in a hundred million, and it does not drift with temperature, age or the state of the electronics. A fluxgate or a Hall sensor must be calibrated against a known field and recalibrated as it ages; a proton magnetometer cannot be wrong about the field except by miscounting the frequency. Magnetic observatories keep one beside their fluxgates for exactly that reason.

Two protons in ten billion

The difficulty is the size of the signal. A coil picks up the precession because the precessing magnetisation of the sample changes the flux through it, and the magnetisation is the net excess of protons pointing one way rather than the other. A proton’s spin along any axis takes only two values, as the experiment that defines spin and cannot be done on it described for silver atoms split into two beams, so in a field each proton is either with it or against it. In thermal equilibrium that excess is set by the ratio of the magnetic energy to the thermal energy: the moment in the field has energies ±ℏγB/2\pm\hbar\gamma B/2, and the populations differ by the Boltzmann factor,

P=tanh⁡ℏγB2kT.P = \tanh\frac{\hbar\gamma B}{2kT}.

The Earth's field orients two protons in ten billion. The net fraction of protons aligned with a field at 20 °C, tanh(ħγB/2kT), against the field, beside the same for free electrons, whose magnetic moment is 658 times larger. In the Earth's 50 µT field it is 1.7 × 10⁻¹⁰, far too small to induce a measurable voltage in a coil. A coil field of 10 mT raises it to 3.5 × 10⁻⁸, two hundred times more; a hospital scanner's 3 T to 1.0 × 10⁻⁵. Electrons in the Earth's field are polarised as much as protons at 33 mT, which is what an Overhauser magnetometer borrows.
Fig. 2 The net fraction of protons aligned with a field at 20 °C, tanh⁡(ℏγB/2kT)\tanh(\hbar\gamma B/2kT), against the field, beside the same for free electrons, whose magnetic moment is 658 times larger. In the Earth’s 50 µT field it is 1.7×10−101.7 \times 10^{-10}, far too small to induce a measurable voltage in a coil. A coil field of 10 mT raises it to 3.5×10−83.5 \times 10^{-8}, two hundred times more; a hospital scanner’s 3 T to 1.0×10−51.0 \times 10^{-5}.

In the Earth’s field the excess is 1.7 parts in ten billion. Half a litre of water holds about 3×10253 \times 10^{25} protons, so the excess is still several million billion protons, but their moment precessing at two kilohertz induces a few nanovolts in a coil of a thousand turns — buried under the thermal noise of the coil’s own resistance. The instrument solves the problem by not relying on the Earth’s field to polarise the sample. A current of an ampere or so through the coil makes a field of about ten millitesla, two hundred times the Earth’s and at right angles to it, and after a few seconds — the protons’ relaxation time T1T_1, two seconds or so in water and less in kerosene — the sample’s magnetisation has grown two hundredfold along the coil’s axis.

Then the coil current is switched off. The magnetisation, now large and pointing across the Earth’s field, precesses about the Earth’s field at the Earth’s frequency, and the same coil, connected to an amplifier, hears the precession. The signal is the large polarisation set by the coil, precessing at the small frequency set by the Earth: in effect the instrument borrows a strong field to make a magnetisation and a weak field to read one.

The same trick at the other end of the scale is what the wait that sets the precision described for atomic clocks: separate the preparation of a state from the period of free evolution, so that each can be done in the conditions that suit it.

The switch that must be fast

The coil cannot be switched off instantaneously, and how quickly it is switched off turns out to matter enormously. While the coil is on, the total field on the protons is mostly the coil’s, pointing along the coil; when it is off, the field is the Earth’s alone, at right angles. As the coil current falls, the total field swings round from one direction to the other.

A magnetic moment in a field that changes direction can do one of two things. If the field turns slowly compared with the moment’s own precession about it, the moment keeps precessing about the field as it moves, its cone of precession tilting round with it. That is the adiabatic theorem, which in quantum mechanics says a system kept in an eigenstate of a slowly changing Hamiltonian stays in the corresponding eigenstate. Here the protons were aligned with the coil’s field, and if the field turns slowly they remain aligned with whatever the field is — ending aligned with the Earth’s field. A moment along the field does not precess about it. The coil has been switched off perfectly and there is nothing to hear.

If instead the field turns quickly compared with the precession, the moment cannot follow; it is left pointing where the coil put it, across the Earth’s field, and precesses about it with its full amplitude.

Switched off too slowly, the coil leaves nothing to measure. The fraction of a water sample's magnetisation left perpendicular to the Earth's 50 µT field, and so free to precess, after a 10 mT polarising field at right angles to it is switched off linearly in a given time, from the Bloch equation for the precessing moment. Switched off in microseconds the moment is left where the coil put it and all of it precesses. Switched off slowly, the moment follows the turning field round, as the adiabatic theorem requires, and ends lined up with the Earth's field where it cannot precess at all. The change happens near Bₚ/γBₑ² = 15.0 ms; half the signal is lost by 32 ms.
Fig. 3 The fraction of a water sample’s magnetisation left perpendicular to the Earth’s 50 µT field, and so free to precess, after a 10 mT polarising field at right angles to it is switched off linearly in a given time, from the Bloch equation for the precessing moment. Switched off in microseconds the moment is left where the coil put it and all of it precesses. Switched off slowly, the moment follows the turning field round and ends lined up with the Earth’s field where it cannot precess at all. The change happens near Bp/γBe2=15B_p/\gamma B_e^2 = 15 ms.

The two regimes are separated by a comparison of rates at the moment the field turns fastest. With a linear switch-off over a time τ\tau, the total field’s direction swings most rapidly as the coil’s field falls through the Earth’s, at an angular rate of about Bp/τBeB_p/\tau B_e; the protons’ precession rate there is about γBe\gamma B_e. The switch-off is adiabatic, and the signal lost, when the first is much smaller than the second, τ≫Bp/γBe2\tau \gg B_p/\gamma B_e^2 — fifteen milliseconds for a ten-millitesla coil in a fifty-microtesla field. The figure integrates the equation of motion for the precessing moment through the whole switch-off, and the full signal survives below about a millisecond, half of it is gone by about thirty milliseconds, and nearly all of it is gone by a tenth of a second.

The coil’s own inductance is the obstacle. A coil of a thousand turns carrying an ampere stores enough energy that switching it off abruptly makes a voltage spike of hundreds of volts, and the circuits that switch it — relays in early instruments, transistors and clamping diodes later — are designed to dump that energy in about a millisecond without letting the current linger. Instruments with a slow switch-off read low or not at all, and a proton magnetometer that has gone quiet is often one whose switching circuit has slowed.

Seen from the other side, the adiabatic following is a useful technique in its own right. Nuclear magnetic resonance and quantum computing both use adiabatic passage to turn a spin smoothly from one direction to another without precise control of the timing, by sweeping a field slowly enough that the spin follows. The proton magnetometer is the case where the same effect would destroy the measurement, and the instrument is built to be fast enough to defeat it.

The note and how long it lasts

Once the coil is off, the precession signal decays. Each proton’s moment precesses at the local field’s frequency, and the sample’s signal is the sum of all of them. Two things make them drift out of step. The first is the liquid’s own spin–spin relaxation, T2T_2, a second or two in water, from the fluctuating fields of neighbouring molecules. The second is the external field itself: if the Earth’s field is not uniform across the sample, protons at one end precess faster than protons at the other.

A field that varies across the bottle shortens the note. The envelope of the precession signal from a 10 cm water sample after the polarising coil is switched off, with the protons' own relaxation time T2 = 2 s, in a uniform field and in gradients of 100 and 500 nT per metre. A gradient makes the protons at one end precess faster than those at the other, so their contributions drift out of step and cancel, the first time when the ends differ by a whole turn: 2.35 s at 100 nT/m, 0.47 s at 500. Near a steel pipe or a buried car, where gradients reach thousands of nanotesla per metre, the note dies before it can be counted.
Fig. 4 The envelope of the precession signal from a 10 cm water sample after the polarising coil is switched off, with the protons’ own relaxation time T2=2T_2 = 2 s, in a uniform field and in gradients of 100 and 500 nT per metre. A gradient makes the protons at one end precess faster than those at the other, so their contributions drift out of step and cancel, the first time when the ends differ by a whole turn: 2.35 s at 100 nT/m, 0.47 s at 500.

In a gradient of 500 nanotesla per metre across a ten-centimetre bottle, the two ends differ by fifty nanotesla, or 2.1 hertz, and their contributions cancel after about half a second. Near a steel pipe, a parked car or a buried iron object the gradient can reach thousands of nanotesla per metre, and the signal dies in tenths of a second — which is why proton magnetometers carry a specification for the largest gradient they tolerate, and why an archaeological survey loses its readings directly over the iron it is looking for. The fading is reversible in principle: the echo that gives back everything but the wandering found that a spin echo refocuses precisely this kind of dephasing, and some laboratory instruments use echoes, but a field instrument simply makes its bottle smaller or waits for a quieter spot.

Counting, and reading the phase

The instrument’s precision comes from measuring a frequency for as long as the signal lasts. The crudest method is to count whole cycles: in one second at two kilohertz the count is uncertain by one, a part in two thousand, which is 23.5 nanotesla — too coarse for most surveys.

Reading the phase, not counting turns, buys a factor of a thousand. The smallest change of field a proton magnetometer resolves against the length of the signal it measures. Counting whole precession cycles resolves one cycle in the record, 23.5 nT in one second. Reading the phase at each end of the record to 1/SNR of a radian resolves √2/(2π·SNR·T) in frequency, 0.05 nT in a second at a signal-to-noise ratio of 100: about the precision of a survey magnetometer, a part in 1 million of the Earth's field. The record cannot be longer than the signal lasts, so the field's gradient across the sample sets the floor.
Fig. 5 The smallest change of field a proton magnetometer resolves against the length of the signal it measures. Counting whole precession cycles resolves one cycle in the record, 23.5 nT in one second. Reading the phase at each end of the record to 1/SNR1/\mathrm{SNR} of a radian resolves 2/(2π SNR T)\sqrt 2/(2\pi\,\mathrm{SNR}\,T) in frequency, 0.05 nT in a second at a signal-to-noise ratio of 100: about a part in a million of the Earth’s field.

Better instruments measure the phase of the signal at the start and the end of the record rather than counting whole cycles. A sinusoid measured with a signal-to-noise ratio of a hundred has its phase known to about a hundredth of a radian, and the frequency is the phase difference divided by the time between, so the uncertainty in frequency falls as one over the signal-to-noise ratio times the record length. At a signal-to-noise ratio of a hundred and a record of a second, the field is resolved to about 0.05 nanotesla, a part in a million of the Earth’s field, roughly the specification of a good survey instrument. Longer records do better as one over their length, but the record cannot outlast the signal, so the gradient, the relaxation time and the polarisation together set the floor, and the time a reading takes — a few seconds of polarising, a second of listening — sets how many readings a surveyor can take in a day.

What a bottle of protons found

The instrument’s first great discovery was made from ships. In the late 1950s marine geophysicists began towing proton magnetometers in a streamlined float a few hundred metres behind survey vessels, and in 1961 Ronald Mason and Arthur Raff published a map of the field over the sea floor off the west coast of North America. It showed long stripes, tens of kilometres wide and hundreds long, in which the field was alternately a few hundred nanotesla stronger and weaker than average. Nothing comparable had been seen on land. Within two years Frederick Vine and Drummond Matthews, and independently Lawrence Morley, explained the stripes: the ocean floor is made at mid-ocean ridges and spreads away from them, and the basalt records the direction of the Earth’s field at the moment it cooled, so that the stripes are a tape recording of the field’s reversals. The dynamo that reverses with nothing pushing it followed how a dynamo can flip its own field; the proton magnetometer is what showed that the Earth’s had flipped, many times, and the stripes became the decisive evidence for sea-floor spreading.

The signal it measured was a few hundred nanotesla on a background of fifty thousand, a part in a few hundred, read by an instrument that needed no calibration and could be towed for thousands of kilometres without drifting. The rock’s own magnetisation, which nothing keeps a magnetisation for ever found slowly decaying in any magnet, survives in basalt for millions of years because its grains are small enough to hold a single domain each and large enough that thermal energy cannot flip them.

On land the same instrument maps what lies beneath a field without digging: a ditch filled with topsoil richer in magnetic minerals than the subsoil around it changes the field by a few nanotesla, a hearth or kiln whose clay was heated past its Curie point by tens, a buried iron object by more. Two sensors carried one above the other measure the difference between them, a gradient, which removes the slow changes of the Earth’s own field during the survey and leaves only what is in the ground.

The electrons that polarise the protons

The polarisation figure shows a further possibility. Free electrons have a magnetic moment 658 times the proton’s, so in the Earth’s field they are as polarised as protons would be in a field 658 times stronger, about thirty-three millitesla. If the electrons’ polarisation could be handed to the protons, the coil would be unnecessary.

That is what an Overhauser magnetometer does. Its liquid contains a dissolved free radical, a molecule with an unpaired electron, and a radio-frequency field at the electrons’ own resonance — about sixty megahertz, set by the radical’s internal structure rather than by the Earth’s field — stirs up the electron spins. Through the coupling between each electron and the protons nearby, the protons’ populations are driven towards a polarisation several hundred times their thermal value in the same field, by a mechanism Albert Overhauser predicted for metals in 1953 and that was soon found in liquids. The protons can then be read continuously while the radio-frequency field keeps them polarised, without the coil being switched on and off, so the instrument can take several readings a second instead of one every few seconds and uses far less power. The adiabatic switching problem disappears with the switching.

What the instrument cannot tell

A proton magnetometer measures the strength of the field and nothing else. The precession frequency depends on the magnitude of the field, not its direction, so a scalar magnetometer cannot say which way the field points; surveyors who need direction use fluxgates alongside it. It also cannot measure fields much weaker than about ten microtesla, where the precession frequency falls so low that a second’s record holds too few cycles, nor in strong gradients, nor where the field is changing during the reading. Because the polarising field must be at a large angle to the Earth’s for the precession to be large, the bottle has to be oriented roughly at right angles to the field, and readings near the magnetic equator or poles need the sensor tilted accordingly.

The figures use representative numbers, not a particular instrument. The switch-off curve assumes a linear fall of the coil current, where a real switching circuit’s current falls more like an exponential and then is clamped; the crossover time depends on the shape, but its scale is always Bp/γBe2B_p/\gamma B_e^2. The gradient picture uses a slab-shaped sample, for which the signal envelope is a sinc function, where a cylindrical bottle gives a slightly different shape; and the resolution estimate takes the phase noise at each end as independent and ignores the decay of the signal over the record, which in practice is accounted for by fitting.

Still open: magnetometers that count atoms

The proton instrument has been surpassed in sensitivity by optically pumped magnetometers, in which a laser polarises the spins of alkali atoms — caesium, rubidium, potassium — in a vapour cell, and the same laser reads their precession. They reach femtotesla sensitivities in shielded rooms, enough to record the magnetic fields of the human brain without the cryogenic superconducting sensors that used to be needed. In the Earth’s field their performance is limited by effects the proton never had: the atoms’ level structure makes the precession frequency depend slightly on the field’s direction relative to the laser, the so-called heading error, and the scalar reading is no longer exactly absolute. How close optically pumped sensors can come to the proton’s absoluteness while keeping their sensitivity — whether atomic magnetometers can become primary standards rather than secondary ones — is being worked on, and for now observatories still keep a bottle of protons as the reference.

A proton precesses about a field at (γ/2π)B(\gamma/2\pi)B with γ/2π=42.577\gamma/2\pi = 42.577 Hz per microtesla, a constant of nature, so the Earth’s field is an audio tone — 2,128.9 Hz at 50 µT — and measuring the tone measures the field absolutely. The Earth’s field polarises only 1.7×10−101.7 \times 10^{-10} of the protons, so the sample is polarised two hundred times more by a coil and the coil switched off; it must go off in well under Bp/γBe2=15B_p/\gamma B_e^2 = 15 ms, because a field that turns slowly drags the moments round with it, by the adiabatic theorem, and leaves them along the Earth’s field where they cannot precess.