The charge a field gives a speck until no line reaches it
Assumes: The path a charge takes is not its field line · The inside of a conductor, where the field is exactly nothing
A coal-fired power station burns several hundred tonnes of coal an hour, and the ash in it, a tenth or more of its weight, leaves the furnace as a dust of glassy spheres carried in the flue gas. Before the gas reaches the chimney it passes through a chamber the size of a house, lined with steel plates a few tens of centimetres apart, with thin wires hanging between them at sixty or seventy thousand volts. More than ninety-nine per cent of the ash stays behind, on the plates. The device is an electrostatic precipitator, invented by Frederick Cottrell in 1907, and nothing in it moves except the gas.
It works by putting electric charge on each speck of ash and then letting the field pull the charged speck sideways onto a plate. The second half is ordinary: a charge in a field feels a force. The first half is the part worth drawing, because the way a speck takes up charge is the one situation in which a field line, usually a drawing convention, becomes a literal path — and the speck’s own charge then redraws the lines until none of them reaches it.
When a field line is a path
Field lines are a choice, not a discovery insisted that nothing in space is arranged in lines, and the path a charge takes is not its field line showed how badly the picture misleads if a line is read as a route: a charge released beside a dipole sets off along its line and then swings wide of it, carried by the speed it has gained. That essay closed by naming the two exceptions. A magnetic field can hold a charge to its line; and so can drag, if it is strong enough that the charge never has a speed of its own.
Ions in air are that second case. An ion at atmospheric pressure collides with gas molecules ten billion times a second, and between collisions it gains almost nothing. Its motion averages to a steady drift in the direction of the field, at a speed proportional to the field: , with a mobility of about two square centimetres per volt-second for the small ions a corona discharge makes. In a field of five kilovolts per centimetre that is a hundred metres a second — fast, but always along the field, never overshooting it. The ion’s path is the field line it started on.
A precipitator makes its ions in the thin sheath of glowing gas round each high-voltage wire, where the glow a thin wire wears before it sparks found the field strong enough to break the air down in a layer a fraction of a millimetre thick. Outside that layer the field is too weak to make more ions, and the ions of the wire’s polarity — usually negative, since a negative corona is steadier — drift out across the whole gap towards the plates in a continuous rain. Every speck of ash in the gas sits in that rain.
The lines a sphere gathers
Take the speck to be a small conducting sphere in an otherwise uniform field. The inside of a conductor, where the field is exactly nothing required that the field lines meet a conductor’s surface at right angles, and an uncharged sphere satisfies that by distorting the field around it: the lines bend in towards it, crowd onto the face that looks upstream and leave from the face that looks downstream. At the two poles the field at the surface is three times the applied field, and at the equator it is zero.
The lines that end on the upstream face are exactly the paths of the ions that hit the sphere. Count them far upstream, where the field is uniform, and they fill a circle of radius around the axis — the flux into the upstream hemisphere is , and in a uniform field a flux of crosses a disc of radius . The sphere’s collecting area is three times its own cross-section, because a conductor gathers field lines from around it. The sphere does not attract the ions by any force of its own; it is uncharged. It simply bends the lines along which the ions are obliged to travel.
As ions arrive the sphere becomes charged with their sign, and a charge on the sphere adds a radial field pointing outward from it. On the upstream face the two fields oppose, and the region of the surface where the field still points inward shrinks to a cap around the upstream pole. With charge , the surface field is , and the lines that still end on the sphere come from a narrower circle upstream, of radius . At
the radial field at the upstream pole exactly cancels the concentrated applied field, the inflow region shrinks to a point, and no field line from upstream reaches the sphere. Every ion’s path goes round. The sphere has charged itself until it is invisible to the rain.
This is called the Pauthenier limit, after the French physicist Marcel Pauthenier who derived it in 1932, and it is a pure field-line result: nothing in it depends on the ions’ mobility, their density or how long they have been arriving, only on the field and the sphere’s size. A particle ten micrometres across in a field of five kilovolts per centimetre saturates at about 26,000 elementary charges. Put another way, the saturated sphere sits at a potential above the field it is in — the charge a sphere of capacitance holds, as how much charge a shape will hold, before anything is charged wrote it, at the potential of three radii’s worth of the applied field. For the ten-micrometre particle that is 7.5 volts. The charge cannot climb higher by waiting, by adding ions or by making them faster; only a stronger field or a larger particle raises it.
The saturation also explains why the charging step cannot be skipped. An uncharged particle in a uniform field feels no net force at all: the field induces a dipole in it, and a dipole in a uniform field is pushed equally both ways. The attraction that needs no charge found that a neutral body is drawn only where the field changes from place to place, and in the wide uniform gap between a precipitator’s plates that pull is negligible. The ions are what turn a neutral speck, which the field merely polarises, into a charged one, which the field moves.
A dielectric sphere distorts the field less than a conductor, concentrating it by rather than by 3, and saturates proportionally lower — at 1.67 rather than 3 for a permittivity of 2.5, typical of fly ash and of most plastics.
How fast the lines close
The rate at which charge arrives is the ion current density times the area of inflow, which for ions moving at along the lines is times the field flux entering the sphere — the same flux that defined the capture circle. It falls as the square of the shrinking capture radius:
where is the ions’ charge density. The equation integrates to a simple form, : half the saturation charge after one , nine-tenths after nine, and the last per cent taking a hundred.
The time constant has a pleasing structure. It depends on the ions alone — their number and their mobility — and not on the particle’s size, so every particle in the stream reaches half its own saturation charge in the same time, whatever its saturation charge is. With half a million ions per cubic millimetre, a density typical of a precipitator’s charging zone, is 2.2 milliseconds. Gas crosses a precipitator in several seconds, so in practice every particle leaves the charging region close to saturation, and the limit, not the rate, decides how much charge it carries. The quantity is the same one that sets how quickly a slightly conducting medium relaxes a charge imbalance: it is the dielectric relaxation time of the ion stream, here measured by a sphere.
The same number turns up in the familiar experience of a balloon rubbed on a jumper and stuck to a wall: in dry winter air, with few ions, the balloon holds for hours; in humid summer air, or near a flame, it falls in minutes, because ions from the surroundings neutralise it at a rate set by their density and mobility. The water drops that charge themselves to a spark found Kelvin’s water dropper fighting the same leak through the air of the room.
Two ways to catch an ion
The field-line picture assumes that the ions go where the field sends them and nowhere else. They also wander. An ion in air has a thermal speed of a few hundred metres a second between collisions, and over a millisecond it random-walks a distance comparable with a small particle’s size. A particle well below a micrometre can therefore gather ions that diffuse onto it from field lines that pass it by, and this diffusion charging does not saturate in the same way: an ion arriving by its own thermal motion is repelled by the particle’s charge only through a Boltzmann factor, so the charge keeps creeping up, logarithmically in time.
The two mechanisms scale differently with size. Field charging gives a charge proportional to the particle’s area, , because the capture circle is a fixed multiple of its cross-section. Diffusion charging, in the approximate formula Harvey White published in 1951, gives a charge that grows roughly as the diameter: a particle’s potential grows as charge over radius, and ions with a thermal energy stop arriving once that potential is a few times . Above about a micrometre field charging wins by a large factor; below about two-tenths of a micrometre diffusion charging dominates; near a quarter of a micrometre they are comparable and each gives only about twenty charges. At a tenth of a micrometre a particle carries two or three charges, and at a hundredth of a micrometre most particles carry none for part of the time, so that charging becomes a matter of statistics rather than of averages. The electrons that pay in fixed amounts recalled that Millikan measured the electron’s charge on oil drops carrying a handful of charges each; precipitator particles a tenth of a micrometre across are in the same regime.
Drift, and the particles that get away
A charged particle in the collecting field drifts towards a plate at the speed at which the electric force balances the gas’s drag. For a sphere much larger than the gas molecules’ free path the drag is Stokes’s, , the same law the drag a distant wall decides followed down to the boundaries that modify it, so
where is a correction, Cunningham’s, for particles small enough that the gas no longer behaves as a continuum around them and they slip between its molecules. With field charging, grows as and the drag as , so the drift speed grows in proportion to size.
Going down in size, the drift speed falls with the field charge, but two things rescue the smallest particles. Diffusion charging gives them more charge than field charging alone would, and Cunningham’s correction, which reaches a factor of three at a tenth of a micrometre and twenty at a hundredth, lets them slip through the gas. The drift speed therefore has a minimum, near two-tenths of a micrometre in this model, where a particle is too small for the field lines to give it much charge and too large for slip and diffusion to make up for it.
A precipitator’s catch follows from the drift speed. Gas carries the particles along the plates while they drift towards them, and turbulence keeps re-mixing the particles across the channel, so that in each short length a fixed fraction of those still airborne reaches the plate. Walther Deutsch’s formula of 1922, refined by Evald Anderson, gives the escaping fraction as , where is the collecting area per unit flow of gas — about sixty square metres per cubic metre per second in a typical installation.
The consequence is a window of particle sizes that a precipitator handles worst. Large particles are caught almost completely; very fine ones are caught better than the middle; and the particles near a few tenths of a micrometre are the ones that get out. The exponential has a second consequence worth knowing: doubling the collecting area does not halve the escaping fraction but squares it, so going from 99 to 99.99 per cent needs only twice the plate, which is why precipitators are built so large and so efficient. Measured penetration curves of real precipitators do show a minimum in efficiency between about 0.1 and 1 micrometre, a fact that shaped regulations on fine particles once their health effects were understood.
Paint that reaches the back of the panel
The same charging runs in reverse in a spray booth. An electrostatic paint gun charges its droplets or powder grains, by a corona at its nozzle or by friction in its barrel, and the car body or the steel cabinet being painted is earthed. The charged droplets then follow, roughly, the field lines from the gun to the work — roughly, because droplets are heavier than ions and their inertia carries them some way off their lines before drag pulls them back, which is the overshoot the essay on charge paths described. Field lines from the gun end all over the earthed object, including on its back faces, and the paint goes with them; a lamp post sprayed from one side comes out coated all round. The finish is self-levelling in the same way that a speck’s charging is self-limiting, since a part already coated with an insulating film of charged paint repels the next droplets towards the bare metal beside it.
A photocopier and a laser printer use the field-charging picture directly, twice. A corona wire lays a uniform charge on the photoconductive drum, and the charge saturates in the same way, at the point where the surface’s own field turns the corona’s ions away. Light then discharges the parts of the drum that should be blank, and toner grains, themselves charged by friction, are drawn onto the parts that still carry charge. The density of toner a printed area takes up is limited, like a speck’s charge, by the field the toner’s own charge sets up against the next grains.
The contrast with dust in a glowing gas is worth drawing. The dust a plasma freezes into a crystal followed grains in a discharge that is full of free electrons as well as ions, where there is no drift along field lines at all, only thermal arrival from every direction; the grain charges until electrons and ions arrive at equal rates, which, because electrons are so much faster, leaves it strongly negative whatever its size. A precipitator’s charging zone is the other extreme, a rain of ions of one sign moving along the field, and the charge a particle takes is set by the geometry of field lines rather than by a balance of thermal fluxes.
What the drawing cannot carry
The capture picture treats one isolated sphere in a uniform field with a uniform rain of ions. In a real precipitator the field varies across the gap, strongest near the wires; the ions’ own space charge, and the charge on the dust itself, distorts the field; and particles are irregular, so the factor of three for a sphere is only an indication. The model’s drift speeds are those of theory, and they are optimistic: precipitator designers work with an empirical “effective migration velocity”, fitted to the catch of real installations, which is typically several times smaller than the theoretical value, because turbulence, re-entrainment of dust from the plates when they are rapped clean, and gas bypassing the plates all reduce the catch.
The Deutsch formula assumes complete mixing across the channel, which is closer to the truth than the opposite assumption of laminar flow but is still a model. The diffusion-charging formula is White’s approximate one, which neglects the field during diffusion charging and the image force that draws an ion onto a particle at close range; combined treatments exist and give somewhat higher charges in the transition region. And the resistivity of the dust, which this picture ignores, matters enormously in practice: highly resistive ash cannot pass its charge to the plate, builds up a charged layer that sparks back into the gas, and can make a precipitator useless, which is why power stations burning low-sulphur coal sometimes have to add sulphur trioxide to the flue gas to make the ash conduct.
Still open: the particles too small to charge reliably
At a hundredth of a micrometre and below, the average charge falls below one elementary charge, and a particle either carries a charge or does not. What fraction is charged at any moment, and how the fraction depends on the ions of both signs present, was worked out by Norman Fuchs’s theory of 1963, which matches measurements within a few tens of per cent and which is now used to calibrate instruments that sort the smallest atmospheric particles by mobility. But the particles that matter most for health and for cloud formation, the nanometre-scale clusters that grow from gases in the atmosphere, are small enough that the charge they carry changes how they grow — an ion can be the seed around which a cluster forms. How much of the atmosphere’s new-particle formation is helped along by ions made by cosmic rays has been measured in large chamber experiments, and the answer appears to depend strongly on the chemistry; how big the effect is in the real atmosphere, and whether it couples cloud cover to cosmic-ray flux in any measurable way, remains disputed.
Ions in air are dragged so hard by the gas that they travel along field lines, so a speck catches exactly the ions whose lines end on it — from a circle 1.73 of its radii across when uncharged — and its own charge narrows the circle as until, at , no line reaches it. The approach takes with , 2.2 ms in a precipitator; the limit grows as the particle’s area, so drift speed grows with size, diffusion and slip rescue the very smallest, and a precipitator lets through most readily the particles a few tenths of a micrometre across.
Part 8 of 8
This essay is one argument about The field concept. The others:
The objects named here
The third axis, after the field and the reading path: the things themselves, and every essay that touches each one.
Corona dischargeDragElectrostatic precipitatorField linesFluxMobilitySaturation
- Counting what comes out, and never looking inside field lines, flux
- The field outside the solenoid, which is not zero field lines, flux
- The field that makes the other, and only while it is changing field lines, flux
- The field that points against the magnet it is in flux, saturation
- The field with no ends, and the force that does no work field lines, flux